Buckling resistance of partially encased columns embedded on walls under fire from one side

Partially encased columns (PEC) have better fire resistance when compared to bare steel columns, due to the existence of concrete between the flanges. The aim of this study is to develop a new proposal for the calculation of the buckling strength of partially encased columns, embedded on walls, unde...

Full description

Bibliographic Details
Main Author: Piloto, P.A.G. (author)
Other Authors: Gonçales, Nathália (author), Rigobello, Ronaldo (author), Vaz, Mário (author), Guedes, Rui M. (author), Baptista, João S. (author)
Format: conferenceObject
Language:eng
Published: 2022
Subjects:
Online Access:http://hdl.handle.net/10198/24646
Country:Portugal
Oai:oai:bibliotecadigital.ipb.pt:10198/24646