Comparing PAC/UF and conventional clarification with PAC for removing microsystins from natural waters

PAC/UF was investigated for removing M. aeruginosa cells and microcystins from natural waters and its performance was compared with the conventional clarifi cation with PAC addition (PAC+C/F/S). Ozonated and clarified waters from Tavira’s Water Treatment Plant were used. Both processes achieved an a...

ver descrição completa

Detalhes bibliográficos
Autor principal: Campinas, M. (author)
Outros Autores: Rosa, M. J. (author)
Formato: article
Idioma:eng
Publicado em: 2010
Assuntos:
Texto completo:http://repositorio.lnec.pt:8080/jspui/handle/123456789/1000265
País:Portugal
Oai:oai:localhost:123456789/1000265