Partially encased section: strength and stiffness under fire conditions
Fire resistance of partially encased sections (HEB and IPE) depends on the temperature evolution during fire exposure. Eurocode 4, part 1.2 [1], proposes the assessment of the cross section using the method of the four components under fire (flanges, web, concrete and reinforcement). This study aims...
Main Author: | |
---|---|
Other Authors: | , , |
Format: | conferenceObject |
Language: | eng |
Published: |
2018
|
Subjects: | |
Online Access: | http://hdl.handle.net/10198/16745 |
Country: | Portugal |