Integrity, Reliability & Failure in refrigeration systems for draught drinks

A refrigeration system for draught drinks was monitored in order to evaluate its thermal performance using temperature, pressure and flow sensors. The first attempt to monitor the temperature of this machine was not successfully accomplished due to the failure of the thermistors used. All the system...

Full description

Bibliographic Details
Main Author: Clito F. Afonso (author)
Other Authors: João Faria (author), Armando Oliveira (author), Ricardo Reis (author), Joaquim Gabriel (author), Armando Araújo (author), Miguel Tavares (author), Jorge Pires (author), Cristina Silva (author)
Format: book
Language:eng
Published: 2013
Subjects:
Online Access:https://hdl.handle.net/10216/101078
Country:Portugal
Oai:oai:repositorio-aberto.up.pt:10216/101078
Description
Summary:A refrigeration system for draught drinks was monitored in order to evaluate its thermal performance using temperature, pressure and flow sensors. The first attempt to monitor the temperature of this machine was not successfully accomplished due to the failure of the thermistors used. All the system was repaired, and the sensors replaced by new ones with a special coating of epoxy to withstand the condensation around. Further tests were carried out with these new sensors, and integrity and reliability were achieved. The measured temperatures, pressure and flow rates of the refrigerant used in the refrigeration machine itself are in accordance with the simulations obtained based on thermodynamics analysis. In that way all the experiments carried out were validated. This paper presents the results of operation of the machine both in a simulation environment and in a real situation.