Three-dimensional effects in laminar flow past a confined cylinder

An experimental and numerical study on the Newtonian fluid flow around a confined cylinder placed in a rectangular duct was undertaken in order to assess three-dimensional effects on the flow patterns. The cylinder was placed at the mid-plane to define a symmetric geometry with a 50% blockage ratio...

ver descrição completa

Detalhes bibliográficos
Autor principal: V. M. Ribeiro (author)
Outros Autores: P. M. Coelho (author), F. T. Pinho (author), M. A. Alves (author)
Formato: article
Idioma:eng
Publicado em: 2012
Assuntos:
Texto completo:https://hdl.handle.net/10216/105169
País:Portugal
Oai:oai:repositorio-aberto.up.pt:10216/105169