Temperature, flow and eccentricity measurements in a journal bearing with a single axial groove at 90º to the load line

Parametric experiments have been conducted to analyse the influence of some supply conditions on the performance of a steadily loaded journal bearing. Temperature distribution on the internal surface, flowrate and bearing eccentricity were measured for different sets of operating conditions, at vari...