Crack constitutive model for the prediction of punching failure modes of fiber reinforced concrete laminar structures

The capability of a multi-directional fixed smeared crack constitutive model to simulate the flexural/punching failure modes of fiber reinforced concrete (FRC) laminar structures is discussed. The constitutive model is implemented in a computer program based on the finite element method, where the F...

ver descrição completa

Detalhes bibliográficos
Autor principal: Barros, Joaquim A. O. (author)
Outros Autores: Gouveia, A. Ventura (author), Azevedo, Álvaro F. M. (author)
Formato: article
Idioma:eng
Publicado em: 2011
Assuntos:
Texto completo:http://hdl.handle.net/1822/12751
País:Portugal
Oai:oai:repositorium.sdum.uminho.pt:1822/12751