Oscillatory and alternate flows in a microfluidic device

The mixing properties of systems with oscillatory or alternate flows are studied by numerical methods. Preliminary results show that, for alternate flows, the contact area between high and low concentration regions increases and mixing is achieved from the combination of transversal diffusion and ax...

Full description

Bibliographic Details
Main Author: Oliveira, Hugo Carneiro (author)
Other Authors: Miranda, J. M. (author), Teixeira, J. A. (author), Vicente, A. A. (author), Correia, J. H. (author), Minas, Graça (author)
Format: conferencePaper
Language:eng
Published: 2006
Subjects:
Online Access:http://hdl.handle.net/1822/5639
Country:Portugal
Oai:oai:repositorium.sdum.uminho.pt:1822/5639
Description
Summary:The mixing properties of systems with oscillatory or alternate flows are studied by numerical methods. Preliminary results show that, for alternate flows, the contact area between high and low concentration regions increases and mixing is achieved from the combination of transversal diffusion and axial advection. The improvement in the mixing process shows that this method is very useful for designing mixers in lab-on-a-chip devices.