Biological treatment of a contaminated gaseous emission containing monochlorobenzene

This study presents the operation of a biotrickling filter when treating a monochlorobenzene (MCB) contaminated gaseous emission. Treatment dynamics were characterised by exposing the reactor to various MCB Organic Loads (OL). The use of different growth support materials, namely limestone, sand, ce...

ver descrição completa

Detalhes bibliográficos
Autor principal: Bastos, F. S. C. (author)
Outros Autores: Rangel, António O. S. S. (author), Castro, P. M. L. (author), Jorge, R. M. Ferreira (author)
Formato: article
Idioma:eng
Publicado em: 2011
Assuntos:
Texto completo:http://hdl.handle.net/10400.14/6780
País:Portugal
Oai:oai:repositorio.ucp.pt:10400.14/6780