Surface, microstructural, and adhesion strength investigations of a bioactive hydroxyapatite-titanium oxide ceramic coating applied to Ti-6Al-4V alloys by plasma thermal spraying

Ti-6Al-4V alloy is employed in implants because of its good mechanical strength, excellent biocompatibility, and good resistance to corrosion in biological environments. Herein, a composite (HAp-TiO2, 50% by volume of both components) coating surface employing Ti-6Al-4V was characterized. Samples we...

ver descrição completa

Detalhes bibliográficos
Autor principal: Rocha,Renan Carreiro (author)
Outros Autores: Galdino,André Gustavo de Sousa (author), Silva,Sidnei Nicodemos da (author), Machado,Marcelo Lucas Pereira (author)
Formato: article
Idioma:eng
Publicado em: 2018
Assuntos:
Texto completo:http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1516-14392018000400224
País:Brasil
Oai:oai:scielo:S1516-14392018000400224