Case study : comparison between the acoustic performance of a mixed building technology building and a conventional building

The objective of this work is to compare the acoustical performance of MBT (Mixed Building Technology) constructions and conventional buildings. The sound insulation performance of a MBT construction was assessed by tests done in situ. The results were compared with similar data from earlier measure...

Full description

Bibliographic Details
Main Author: Bragança, L. (author)
Other Authors: Patrício, Jorge (author)
Format: article
Language:eng
Published: 2004
Subjects:
Online Access:http://hdl.handle.net/1822/5550
Country:Portugal
Oai:oai:repositorium.sdum.uminho.pt:1822/5550
Description
Summary:The objective of this work is to compare the acoustical performance of MBT (Mixed Building Technology) constructions and conventional buildings. The sound insulation performance of a MBT construction was assessed by tests done in situ. The results were compared with similar data from earlier measurements undertaken by the Building Physics Laboratory of the University of Minho in Portugal, and from simplified prediction methods. The building where this comparison was done is a 3-storey building. The first 2 storeys were refurbished using conventional construction methods, but the 3rd storey was built using MBT methods, characterised by using lightweight materials, with high thermal insulation, and large fenestration areas. Based on the work undertaken, some conclusions and proposals for further work are presented.