Electrochemical Reduction behaviour of Donepezil at β-Cyclodextrin Modified Carbon Paste Electrode

A simple, accurate and sensitive voltammetric method for determination of donepezil (DNZ) using β-cyclodextrin modified carbon paste electrode (CDMCPE) is developed. CDMCPE exhibited significantly increased sensitivity and selectivity for DNZ compared to the bare carbon paste electrode (CPE). Effect...

Full description

Bibliographic Details
Main Author: Rao,C.N. (author)
Other Authors: Subbarayudu,K. (author), Venkateswarlu,P. (author)
Format: article
Language:eng
Published: 2010
Subjects:
Online Access:http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042010000500006
Country:Portugal
Oai:oai:scielo:S0872-19042010000500006
Description
Summary:A simple, accurate and sensitive voltammetric method for determination of donepezil (DNZ) using β-cyclodextrin modified carbon paste electrode (CDMCPE) is developed. CDMCPE exhibited significantly increased sensitivity and selectivity for DNZ compared to the bare carbon paste electrode (CPE). Effect of accumulation potential, accumulation time, pH of buffer, etc., on peak currents for the determination of DNZ was studied using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). Peak currents showed a linear response in the concentration range 4.2 x 10-8 to 5.6 x10-7 M and 3.2 x 10-9 to 4.2 x 10-8 M at CPE and CDMCPE respectively. Limit of detection (LOD) and limit of quantification (LOQ) were found to be 1.2 x 10-9 and 0.40 x 10-8 M. The proposed method has been successfully applied for the determination of DNZ in spiked urine samples, serum samples and pharmaceutical formulations.