Partially encased columns eon wall under fire from one side

The steel columns have a great loadbearing capacity, however when exposed to fire conditions are heated in a relatively short period. The steel-concrete composite columns consist in an excellent alternative solution to bare steel column. Partially Encased Columns (PEC) have higher strength and stiff...

Full description

Bibliographic Details
Main Author: Piloto, P.A.G. (author)
Other Authors: Gonçales, Nathália (author), Rigobello, Ronaldo (author), Vaz, Mário (author), Guedes, Rui M. (author), Baptista, João S. (author)
Format: conferenceObject
Language:eng
Published: 2020
Subjects:
Online Access:http://hdl.handle.net/10198/21653
Country:Portugal