Adhesion failures on hard coatings induced by interface anomalies
In this work, the lack of adhesion occurred during the up-scaling of the deposition of tribological coatings in a semi-industrial apparatus is interpreted. The adhesion problems were detected for both hard and self-lubricant coatings from W-Ti-N and W:C systems, respectively, when they were deposite...