Axial buckling load of partially encased columns under fire – new formulae

Fire resistance of partially encased columns (HEB and IPE) depends on the temperature evolution during fire exposure. This paper aims to assess de effect of the balanced summation model into the design of the axial buckling load of partially encased columns under fire, according to EN 1994-1-2. New...

Full description

Bibliographic Details
Main Author: Piloto, P.A.G. (author)
Other Authors: Mesquita, L.M.R. (author), Ramos Gavilán, Ana Belén (author), Almeida, David (author)
Format: conferenceObject
Language:eng
Published: 2018
Online Access:http://hdl.handle.net/10198/16840
Country:Portugal
Oai:oai:bibliotecadigital.ipb.pt:10198/16840